D3-16td1-1. ZL-RTB-DB09 ZL-RTB-DB15 ZL-RTB. D3-16td1-1

 
 ZL-RTB-DB09 ZL-RTB-DB15 ZL-RTBD3-16td1-1  This page offer our General catalog, Technical manual, list of products that have accreditation mark, and etc

Fuse Connector Module ZL-CM16TF2 Cables and PLC I/O Modules. Quick view. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Links to reduce . 1 DCS Center. ZL-CM40. GENERAL CATALOG 2016 619 Certification PLC HMI SENSOR ENCODER COUNTER INFORMATION D4 Series UL PZ Series CUL CE Class 1 Div 2 Analog Modules D3 Series NK UL PZ1-8ND1-6TD1 CPU CUL CE F4-04AD PZ1-8ND1-6TD1-A SR-21-EX F4-04ADS PZ1-8ND1-6TR1 D3-330 F4-08AD PZ1-8ND1-6TR1-A SA-21-EX F4-16AD-1 PZ1-R D3. Specifications of the D3-16TD1-1:Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. $158. Step 3 Select the cable length by replacing the # symbol with: Blank = 0. Fast Delivery 12-month warrantyWARNING Thank you for purchasing automation equipment from Automationdirect. 25. Multiple model numbers may indicate different products, different components within the products or both. DISCONTINUED BY MANUFACTURER, DL305 DISCRETE OUTPUT MODULE, 16-POINT, 6-24 VDC, SINKING, 2 COMMON(S). 10/2021 - 10 slot base D3-10B-1, D3-EXCBL expansion I/O cable, and Handheld Programmer cable D3-HPCBL have been discontinued with no replacement. ZIP. We want your new automation equipment to operate safely. Please consider Productivity, BRX or CLICK as a replacement PLC platform. D; January 2010 :D3-16TD1-1 Output module has been discontinued with no replacement. We want your new automation equipment to operate safely. 2023 06. 45VDC. ZL-LTB32-24 ZL followed by -RTB followed by 20, 40, 50, -DB09, -DB15, -DB25 or -RJ12. 1 Short Description. Multiple model numbers may indicate different products, different components within the products or both. close26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay Modulesd3-16tr. 1. D3-05B-1 and D3-08TA-2 have been retired as of 09/2021. 5 A/point 3A/common Max Leakage Current 0. D3-10B-1: Adapter JIC 1″x 3/4″ TDS-4S 1: NOV: 56516-16-12S: Adapter JIC 1/4. Note: These I/O addressing configurations are for the bases with “-1” on the end of the part. EA9-T6CL-R T1F-8AD4DA-1 T1K-16B F3-08THM-R D3-16TD1-1 D3-08TD2 D3-08TD-2 D3-08TA-2 D3-08TA-1 D3-04TAS T1H-EBC F3-08THM-T D3-05BDC-NR F3-08THM-K F3-08THM-J F3-08THM-E D3-016TD2 T1F-08AD-1 T1F-16RTD T1F-16DA-2 T1F-16DA-1 T1F-16AD-2 T1F-16AD-1 T1F-14THM T1F-08DA-2 F3-08TRS-5 T1F-08AD-2 P3-16DA-1 D2-262 F3-RTU-1 D3-DCM D3-10BDC-NR D3-10B-NR D3-08B. D3-HPP was discontinued 01/2018. ZL-3CBL3FRD16 cables and connectors pdf manual download. com. 18. 00. . 800-575-5562. We want your new automation equipment to operate safely. Anyone who installs or uses thisWARNING Thank you for purchasing automation equipment from Automationdirect. We want your new automation equipment to operate safely. D3-16TD1-1 has been retired as of 05/2022. Multiple model numbers may indicate different products, different components within the products or both. Current 0. We want your new automation equipment to operate safely. Fast Delivery 12-month warrantyModel Number(s) Model numbers included in the listing. 7 oz. 2023 05. 2023. Koyo D3-16TD1-1 Get a price at EU Automation. This module is also known as the DirectLogic D3-16ND2-1, Siemens Simatic 305-05N, or Koyo E-05N. com™, doing business as, AutomationDirect. 5A Max. . We want your new automation equipment to operate safely. D3-08B-1 . By adding the switch between the supply (+) and the input, the circuit is completed. 16 pt 5-24 VDC NPN (sink) output, 0. 5500 for Availability . 24V N/A OFF to ON Response 0. I/O modules 5-slot local and 5-slot expansions Total I/O: 144 5-slot local and two 5-Slot expansions Total I/O: 224-1 bases Using “-1” bases The D3-350 CPU can be installed in legacy DL305 bases or the “-1” bases. 24. 1 DCS Center. com™, doing business as, AutomationDirect. *These I/O modules have non-removable terminal blocks which can be terminated using the ZL-CBL24-N cable and the ZL-RTB20 module of the ZIPLink Join Product iQ. (180g) F3--08TAS 6. 1mA @ 40VDC. . 3 oz. Consider. Also for: D4-16ta, D3-16td1-2, Dl405, D4-16td1, Zl-cm16tf2, Zl-4cbl2, D4-16td2. This version of Internet Explorer is either no longer supported by Microsoft , or is obsolete and. DC Input Modules D3-08ND2 DC Input $105. WARNING Thank you for purchasing automation equipment from Automationdirect. P3-16TD1 $130. F3-08THM-n [note: n=J,K,T,R,S,E,1,2 versions] Analogue output modules D3-02DA(E-01DA), F3-04DA-1, F3-04DAS Communications modules D3-232-DCU(E-03DM), D3-422-DCU(E-02DM) Special modules D3-08SIM(E-01S), D3-HSC(E-01Z), D3-PWU(C-22P), D3-TCSU(F-10D) Programming devices D3-HP(R-23P), D3-HPP(A-23P) with cable D3. discontinued by manufacturer, plc module rack, directlogic dl305 i/o base, 5-slot, panel mount, external 110-220 v ac required, 24 v dc 100 ma. C 3 C 2 C 1 C 0 Optical Isolator 9VDC L +- - 5--24VDC 5A Common Output 24VDC DC Output Modules D3-04TD1 DC Output (Obsolete - No longer available)Koyo D3-16TD1-1 Get a price at EU Automation. 25. . Worldwide Shipping available. D3-10BDC . WARNING Thank you for purchasing automation equipment from Automationdirect. 1 DCS Center. Model Number(s) Model numbers included in the listing. Koyo D3-16TD1-1 Get a price at EU Automation. com™, doing business as, AutomationDirect. 4 dl305 zl-3cbl2fr16 d3-16td1-1 zl-cm16rl24a dl305 zl-3cbl2fr16 d3-16td2 zl-cm16rl24a warning : wire only according to wiring diagrams shown below to avoid causing damage to the plc or connector module. 18. 24. 5 amp / point, 2 amp / common, removable terminal. ›. Consider BRX, Productivity, or CLICK PLC systems as upgrades. AC or DC relay output modules. The D3 series is a free location type that allows free selection of the balance and type of input/output and up to 168 points. 25. Anyone who installs or uses thisKoyo D3-16TD1-1 Pyydä hinta yritykseltä EU Automation. 8 kΩ Input Current12mA max Minimum ON. 10 . KOYO, OUTPUT; Send Enquiry. Anyone who installs or uses thisD3-16TD1-1 D3-16TD2 0 0 0 0 20 30 40 180 24 0 96 0 0 0 0 AC Output Modules F3-08TAS-1 F3-16TA-2 D3-16TA-2 0 0 0 200 250 400 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules D3. com™, doing business as, AutomationDirect. $158. Link . 24. Consider BRX, Productivity, or CLICK PLC systems as upgrades. com™, doing business as, AutomationDirect. 2022. ) Compatibility Matrix Chart For DL05/06 PLCs I/O Modules Feed-through Modules Relay Modules Fuse Modules LED Modules 1F I/O Addressing Conventional Method In This Appendix. Anyone who installs or uses thisii Table of Contents DL305 User Manual, Rev. WARNING Thank you for purchasing automation equipment from Automationdirect. VAT) €195. Model Number(s) Model numbers included in the listing. 1) Prices as of April 16, 2014. Automationdirect's ZL-CM40 is a specifying an i/o wiring system. 24V 6 mA/ON pt Output type NPN transistorD3-16TD1-1 16 24 V DC Sink 160 Open D3-08TA-2 8 100/200 V AC 180 Open D3-16TD2 16 24 V DC Source 200 Open A na log I p ut/ M d e Model Number Input Output Weight (g) Price P oi nts Fu c D3-02DA 0 to 10 V DC/4 to 20 mA 200 Open Sp ecia lModu Model Number Function Weight (g) PriceD3-16TD1-1 D3-16TD2 0 0 0 0 20 30 40 180 24 0 96 0 0 0 0 AC Output Modules F3-08TAS-1 D3-08TA-1 D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 200 160 160 250 400 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-05BDC-NR 900 900 900 900 900 900 900 2000. Page 2 of 6 aa ee oa oeo o age ae afe e ao of aa. pio DL205 D2-32TD1. 10/2021 - 10 slot base D3-10B-1, D3-EXCBL expansion I/O cable, and Handheld Programmer cable D3-HPCBL have been discontinued with no replacement. We want your new automation equipment to operate safely. 4 oz. The P3-16TD1 DC Output Module provides 16 6-27 VDC sinking outputs with 2 isolated commons for use with the Productivity3000 Programmable Automation Controller. f2-08ta 8pt 24-140vac output high current 1. Primary Steel, Tier 1 and 2 Suppliers as well as Research Dynamometer. Multiple model numbers may indicate different products, different components within the products or both. This Koyo design revolutionized the small PLC market, and is still a good performer and a great value. 16 (current sinking) Commons per Module. 3 oz. D3-16TR Output Module Model: DirectLogic 305 Qty: Ask. WARNING Thank you for purchasing automation equipment from Automationdirect. 35 e aa aa Page 1 of 5 Product Family: DateDL305 Manual Number D3-USER-M Revision and Date 1st Edition, Rev. Please call or email us with your request. 5A 1A L 5A Output Common 80--265VAC 9V 10 AmbientT emperature. Model Number(s) Model numbers included in the listing. 00. (Note that discrete high current and analog modules are not supported by ZIPLinks and must be traditionally wired using terminal blocks such as DINnectors. 5 mA/ON pt. Multiple model numbers may indicate different products, different components within the products or both. ZIP. Giá bán D3-16TD1-1 - Mô đun Digital (DL-305) 16DO 6-27VDC Koyo - Discrete Output Module, Discrete Output: 16-point, 6-27 VDC Sink. 16. Programmable Controllers Certified for Canadapdf Datasheet D3-16TD1-1 (pdf, 377 KB) Download ( pdf, 377 KB ) pdf Datasheet D3-16TD1-2 (pdf, 428 KB)D3-08TD1 DC Output <---> Outputs per Module 8 (current sinking) Commons per Module 2 (internally connected) Operating Voltage 5-24VDC Output Type NPN (open collector) Peak Voltage 45VDC N/A ON Voltage Drop 0. D3-16TD1-1 16 24 V DC Sink 160 Open D3-08TA-2 8 100/200 V AC 180 Open D3-16TD2 16 24 V DC Source 200 Open Analog Input/output Module Model Number Input OutputKoyo D3-16TD1-1 Get a price at EU Automation. Cable Multi-Conductor. 24. 24. D3-04AD ZL followed by -SVC followed by CBL50 with or without, -1, -2 D2-250-1 T1K-01AC ZL may befollowed by -RW or -RFU, F0-08DAH-1 (a) F2-DEVNETS-1 D2-04TD1 P3-32TD1 T1K-16B H2-SERIO-4 D3-350 SE2-SW18U-2G-T SE-SW5U-SC-WT D2-08ND3 D2-16ND3-2 P3-01AC ATM1900T GS followed by -RJ12 or -485HD15 followed by -CBL-2 T1F. D3-232-DCU RS232C Data Communication Unit Model: Qty: Ask. 2022 08. 1 The P3-64ND3, P3-64TD1 and P3-64TD2 modules have two 32-point connectors and require two ZIPLink cables and two ZIPLink connector modules. 25. At Lektronix we can provide you with a brand new Koyo D3-16TD1-1. We want your new automation equipment to operate safely. 06. Phone number: 1-877-854-3577 — Email: D3-16TD1-2 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, SINKING OUTPUT MODULE, 5-28 VDC, 0. aa ee DL305 User Manual Errata0 1 2 3 4 5 6 7 0 2 4 6 C 1 1 3 5 7 C 2 11 0V AC IN PU T D3 --08N A--1 C1 0 1 2 3 4 5 6 7 C2 110VAC 110VAC 110VAC Input Common 2. (180g) F3--08TAS 6. We want your new automation equipment to operate safely. This document also may not show all models included in the listing. This document also may not show all models included in the listing. L Points Derating Chart 0 1 2 3 4 5 6 7 0 2 4 6 C 1 1 3 5 7 C 2 110-220VAC OUTPUT D3--08TA--2 5A 80--265VAC C1 0 1 2 3 4 5 6 7 C2 80--265VAC L L L L L L L 0 2 4 6 8 0. Call 800. com™, doing business as, AutomationDirect. Consider BRX, Productivity, or CLICK PLC systems as upgrades. 26–52 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System, (cont. 2A/pt. 2023 05. WARNING Thank you for purchasing automation equipment from Automationdirect. iE-Series / mTV-100; XE-Series / eMT-Series; cMT-Series. Price: $150. 2022 08. WARNING Thank you for purchasing automation equipment from Automationdirect. (178g) D3--08TA--1 7. Anyone who installs or uses thisD3-10B-1 110/220 V AC 10 1,500 Open D3-10BDC 24 V DC 10 1,500 Open Base Expansion Cable Model Number Function Weight (g) Price. pio DL305 F3-16TA-1. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Ask us about D3-16TD1-2 Repairs. The example below shows a derating curve for a D3--16TD--1 discrete output module where the operating specifications are affected depending on ambient temperature. com. Outputs per Module. 1 DCS Center. DirectLOGIC 305 [Discontinued Model] The DL305 series is a small modular PLC that has been marketed by various name brand PLC manufacturers for over 20 years. 25. We want your new automation equipment to operate safely. 1. d2-16td1-2 16pt 12-24vdc sink (2term) 0. We want your new automation equipment to operate safely. 1 rev 1. Tier 1 and 2 Suppliers as well as Research Dynamometer Laboratories. Nominal Output is 6-24 VDC. in the tools and supplies, misc products category. 06. 21. 2022 08. Model Number(s) Model numbers included in the listing. D3-16TD1-1 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED. D0-16TD1 SE-SW5U-P P3-8AD4DA-1 T1F-08DA-1 D2-ANLG-M D2CTRINT H2-ERM SE-SW9U-ST T1F-16AD-2 F0-CP128 (a) T1K-08TR D2-12TR H0-CTRIO2 ZL-CDM-RJ12 D3-08ND2 ZL-CBL40 followed by -S, -1S, -2S F3-RTU-1 SE-SW10MG-2P FA-ACCUPWR-1 (a) SE2-SW10UG-2P-T H2-ERM100 ZL-RFU40, remote fused terminal block interfaces. ON Voltage Drop 1. Product no longer available from Supplier. Price: €236. 7 oz. Siemens TI 305 | Siemens TI 405 | Siemens TI 505 And other related componentry Distributed Control Systems For Industrial Automation Siemens - Texas InstrumentsKoyo D3-16TD1-1 Get a price at EU Automation. Quality Koyo automation parts. Radwell Independent Supply Chain New Level 1 Call For Pricing. Input And Output Module. AUTOMATION DIRECT. D3-16TD1-1: Element Filter HP32/45 TDS-4S 2: NOV: 83126: Pin Cylinder Lift TDS-4S 1: NOV: 82042: Switch Temp Open on Rise TDS-4. DL305 ZL-3CBL2FR16 D3-16TD1-1 DL305 ZL-3CBL2FR16 D3-16TD2 ZL-CM16TF1 ZL-CM16TF1 - - - 0-1 2 15 Wiring Diagram Output REMOVAL INSTALLATION Fuse Installation And Removal Pg. 5A/pt, 2A/module. Anyone who installs or uses thisD3--04TD1 +- - NC 0 C0 1 C1 2 C2 3 C3 NC L L L L Internally Connected 5--24VDC 02 10 04 30 06 50 0 AmbientT emperature (˚C/˚F) 32 50 68 86 104 1221 40 ˚C ˚F 1A/pt. pio DL305 D3-16ND2-1. We want your new automation equipment to operate safely. 4 dl305 zl-3cbl2fr16 d3-16td1-1 zl-cm16rl24a dl305 zl-3cbl2fr16 d3-16td2 zl-cm16rl24a warning : wire only according to wiring diagrams shown below to Model Number(s) Model numbers included in the listing. 0m, -2 = 2. Automation Direct D3-16TD1-1 Discrete Output Module, 16-Point, 6-24 VDC: Amazon. 5A Max. 21. 24. If your application requires a lot of relay . This document also may not show all models included in the listing. Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. 26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay Modules Model Number(s) Model numbers included in the listing. . com™, doing business as, AutomationDirect. 1 DCS Center. match the correct combination of cable, plc i/o module, and connector module as shown. We want your new automation equipment to operate safely. 18. 自動控制產品 (可程式控制器 PLC / 旋轉編碼器 Encoder),精選商品介紹. 6 oz. 800-575-5562. 2023 11. 35 e aa aa Page 1 of 5 Product Family: DateDL305 Manual Number D3-USER-M Revision and Date 1st Edition, Rev. Product iQ offers professional level information and is free for most users. AUTOMATION DIRECT D3-16TD1-1 DISCRETE OUTPUT MODULE. We want your new automation equipment to operate safely. 1. 06. com™, doing business as, AutomationDirect. com™, doing business as, AutomationDirect. Consider BRX, Productivity, or CLICK PLC systems. Multiple model numbers may indicate different products, different components within the products or both. D3-232-DCU RS232C Data Communication Unit Model: Qty: Ask. Yes. 1 Terminal Blocks and Wiring Solutions 1-800-633-0405 Legacy to New Generation Conversion Guide The following steps and charts will help in converting from the Legacy ZIPLink components to the new generation of ZIPLink wiring solutions. 16 pt 5-24 VDC NPN (sink) output, 0. 5A/point, 2A/common. Local CPU Base. D3-16TD2 Source Output Module Model: Qty: 5. D3-08TD1 is a DirectLogic DL305 discrete sinking 8 output point module. 4 oz. VAT) Availability: 1 available. 2022. 06. Specifications. com™, doing business as, AutomationDirect. . Multiple model numbers may indicate different products, different components within the products or both. We want your new automation equipment to operate safely. 1 DCS Center. 2023 11. Fast Delivery 12-month warrantyii Table of Contents DL350 User Manual, 2nd Edition Agency Approvals. Anyone who installs or uses this17 Discrete Output Modules InThisChapter. Anyone who installs or uses this1 DL350 PLC User Manual Manual Number: D3--350--M DCS Center. DL305 ZL-3CBL1FR8 D3-08TA-1 DL305 ZL-3CBL2FR16 D3-16TA-2 ZL-CM16TF1 ZL-CM16TF1 ZL-CM16TF1 DL305 ZL-3CBL2FR16 D3-16TD1-1 DL305 ZL-3CBL2FR16 D3-16TD2 ZL-CM16TF1 ZL-CM16TF1 - - - 0-1 2 15 Wiring Diagram Output REMOVAL INSTALLATION Fuse Installation And Removal Pg. This page offer our General catalog, Technical manual, list of products that have accreditation mark, and etc. com™, doing business as, AutomationDirect. Product Specs Condition: Open Box Unused item with absolutely no signs of wear. 01. 06. 4. (210g) Relay. ) Compatibility Matrix Chart For 05/06 PLCs I/O Modules Support. 2022 05. We want your new automation equipment to operate safely. SKU: 558135. Quality Koyo automation parts. Model Number(s) Model numbers included in the listing. 2 oz. D3-16TD1-1 Output module has been discontinued with no replacement. D3-16TD1-1: Used/Refurbished: $93. 10/2021 - 10 slot base D3-10B-1, D3-EXCBL expansion I/O cable, and Handheld Programmer cable D3-HPCBL have been discontinued with no replacement. Anyone who installs or uses thisWARNING Thank you for purchasing automation equipment from Automationdirect. GE Fanuc Panel C 320W. 8/common 0. We want your new automation equipment to operate safely. In stock items ship in 1-2 days to ensure Radwell's Quality Assurance inspections. 0 1 2 3 4 5 6 7 110--220VACO UTPUT D3--08TA--1 1 C C 2 4 5 6 1 2 3 7 0 Derating Chart 0 2 4 6 8 Points 0. 2023 06. 1ms 0. Multiple model numbers may indicate different products, different components within the products or both. D3-330 DL330 CPU Module Model: DirectLogic 305 Qty: 2. WARNING Thank you for purchasing automation equipment from Automationdirect. 國際性的電子商務平台,提供多品牌的產品銷售以及介紹,產品的內容多以工控相關產品為主,並且透過影片以多元化的方式來介紹產品以及呈現教學案例。. com, a global distributor of electronics components. 18. 1 DCS Center. 2022 05. WARNING Thank you for purchasing automation equipment from Automationdirect. Shop By Phone . com™, doing business as, AutomationDirect. 0m. SA: Stage type. com, a global distributor of electronics components. D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin-ued with no replacement. 5 A/point 2A/commonAutomationdirect's D3-16TD1-1 is a specifying an i/o wiring system. WARNING Thank you for purchasing automation equipment from Automationdirect. 1 DCS Center. This module is also known as the DirectLogic D3-16TD1-1, Siemens Simatic 305-15T, or Koyo E-15T. . 2 oz. EA9-T6CL-R T1F-8AD4DA-1 T1K-16B F3-08THM-R D3-16TD1-1 D3-08TD2 D3-08TD-2 D3-08TA-2 D3-08TA-1 D3-04TAS T1H-EBC F3-08THM-T D3-05BDC-NR F3-08THM-K F3-08THM-J F3-08THM-E D3-016TD2 T1F-08AD-1 T1F-16RTD T1F-16DA-2 T1F-16DA-1 T1F-16AD-2 T1F-16AD-1 T1F-14THM T1F-08DA-2 F3-08TRS-5 T1F-08AD-2 P3-16DA-1 D2. Order toll free: 800. Specifications. (180g) F3--16TA--2 7. (160g) D3--16TD2 7. Terminal Strip. Current 0. Contents: Constructor PLC I/O Library CD version 5 - This library contains over 1800 inactive PLC modules for you to use in your electrical diagrams. 5 A. DC Input Modules. Quality Koyo automation parts. Access Network Pair Cable 2Conductors 2. Model Numbers Overview; D3-02DA 【Function】0 to 10 V DC/4 to 20 mA: Extension IO module Special Module. Shop By Phone . Retired. 8 (current sourcing) Commons per Module. com™, doing business as, AutomationDirect. D3-16TD1-1 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, DL305 DISCRETE OUTPUT MODULE, 16-POINT, 6-24 VDC, SINKING, 2 COMMON(S), 8 POINT(S) PER COMMON, 0. 1 ms 0. 1 DL350 PLC User Manual Manual Number: D3--350--M DCS Center. Weintek HMI Products. Quality Koyo automation parts. Page 2 of 6 aa ee oa oeo o age ae afe e ao of aa. Consider BRX, Productivity, or CLICK PLC systems as upgrades. FA-ACCUPWR-1 P3-RS P3. 5A/point, 2A/common. This document also may not show all models included in the listing. ZL-RTB-DB09 ZL-RTB-DB15 ZL-RTB. 2 To download fullsize color . 1 DCS Center. Add to Cart. D3-16TD1-2 - 16PT 5-24VDC SINK OUTPUT W/24 PIN CON. 2022. WARNING Thank you for purchasing automation equipment from Automationdirect. 0. Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. D3-330P CPU Module Model:. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Anyone who installs or uses thisDL305 ZL-3CBL2FR16 D3-16TD1-1 DL305 ZL-3CBL2FR16 D3-16TD2 ZL-CM16TF1 ZL-CM16TF1 - - - 0-1 2 15 Wiring Diagram Output REMOVAL INSTALLATION Fuse Installation And Removal Pg. Koyo D3-16TD1-1 Get a price at EU Automation.